03 / 04 ESG Reporting

Reporting, from the meter up.

Greenhouse gas inventories and climate disclosures for real estate owners, investors and companies: calculated from utility data, mapped to the standards your investors and lenders use, and ready for assurance.

Axonometric drawing of a typical office building, marked up by emissions scopeScope 1 is marked at the gas-fired boilers and rooftop units, Scope 2 at the electrical service, and Scope 3 at the tenant floors and the waste bins. +38.00±0.00−4.20 Scope 1: gas burned on siteBoilers and rooftop units 1 Scope 2: electricityBought from the grid 2 Scope 3: value chainTenants, waste, suppliers 3

Typical building · modelled

  1. Scope 1. Gas burned on site, in boilers and rooftop units.
  2. Scope 2. Electricity bought from the grid.
  3. Scope 3. The value chain: tenants, waste and suppliers.

Why from the meter

In a typical Toronto office, the gas meter accounts for nearly four-fifths of operational emissions. Get the few meters that matter right, and most of the report is right. We start there, and document every step to the published figure.

01 Scopes

One building, three scopes.

The typical office from our Net Zero Building page, read as an emissions inventory. Choose a source to see its scope, the data behind it and how it is calculated.

Typical building · modelled · 2026 factors

Axonometric drawing of the typical office building, with emission sourcesThe selected emission source is circled in orange on the drawing; details appear alongside. +38.00±0.00−4.20 S1a S1b S2 S3a S3b

S1 Scope 1

Natural gas burned on site

Source
The perimeter boilers and the two rooftop units burn natural gas for heat.
Data
Monthly gas bills or utility interval data, in cubic metres.
Method
Gas use × the emission factor for natural gas from Canada’s National Inventory Report.
This building

352 tCO₂e a year, 79% of Scopes 1 and 2

S1 Scope 1

Refrigerant leaks

Source
The cooling circuits in the rooftop units lose small amounts of refrigerant. Each kilogram can carry a warming effect thousands of times that of CO₂.
Data
Service records: kilograms topped up, by refrigerant type.
Method
Mass lost × the refrigerant’s global warming potential.
This building

Not modelled here: it depends on the building’s actual service records.

S2 Scope 2

Purchased electricity

Source
Electricity bought from the grid for lighting, plug loads, fans, pumps and cooling.
Data
Monthly electricity bills or smart-meter data, in kilowatt-hours.
Method
Location-based: kWh × Ontario’s grid average. Market-based: the factors in your contracts and certificates. The GHG Protocol asks for both.
This building

96 tCO₂e a year, location-based, 21% of Scopes 1 and 2

S3 Scope 3 · Category 13, downstream leased assets

Energy tenants buy themselves

Source
Where tenants contract their own electricity, it leaves the owner’s Scope 2 and is reported as Scope 3.
Data
Tenant meter data, requested under green lease clauses, or documented estimates by floor area.
Method
The same factors as Scope 2, with estimates and coverage disclosed.
This building

In this building the owner buys all the energy, so tenant use is already inside Scopes 1 and 2.

S3 Scope 3 · Category 5, waste generated in operations

Waste from operations

Source
Garbage, recycling and organics collected from the building.
Data
Hauler reports by stream, in tonnes, checked against periodic waste audits.
Method
Tonnes by stream × treatment-specific emission factors.
This building

Not modelled here: it needs hauler data.

All Operational emissions · Toronto, 2026 factors

Most of the footprint sits behind two meters

352 tScope 1, natural gas

96 tScope 2, location-based

36.1 kgCO₂e per m² a year

Scope 1, gas 79%Scope 2, electricity 21%

On Ontario’s grid, a kilowatt-hour of natural gas carries about 2.5 times the emissions of a kilowatt-hour of electricity, so the gas meter dominates the inventory even though electricity makes up 82% of the energy bill. The same numbers feed GRESB, CDP and a CSDS 2 disclosure.

Owner’s view, operational control approach; the owner buys all energy for the building. Emission factors: 0.185 kgCO₂e/kWh for natural gas and 0.074 kgCO₂e/kWh for Ontario’s grid in 2024 (location-based). Refrigerants and waste need building records and are not modelled. Figures are rounded.

02 What we deliver

Numbers that hold up.

  1. 01

    GHG inventory

    Scope 1, 2 and relevant Scope 3 emissions under the GHG Protocol, by building and for the organization, with location- and market-based Scope 2.

  2. 02

    Data management

    Utility and tenant data set up in ENERGY STAR Portfolio Manager or your own platform, with estimates flagged and coverage tracked by building.

  3. 03

    Climate disclosure

    Disclosures aligned with CSDS 2 and IFRS S2 — governance, strategy, risk management, metrics and targets — and answers to CDP and investor questionnaires.

  4. 04

    Targets and transition plans

    Targets with interim milestones, tested against your capital plan and building-by-building decarbonization pathways.

  5. 05

    Assurance readiness

    A documented trail from utility bill to reported figure, prepared for limited or reasonable assurance under ISSA 5000 or CSSA 5000.

  6. 06

    Claims review

    A check that environmental claims in marketing and reports are substantiated, as the Competition Act requires.

Real estate funds and REITs: see GRESB.

03 Landscape

The rules, as they stand.

Canadian climate disclosure is mostly voluntary for now, but investors, lenders and regulators are converging on the same standards. Reporting to them now makes a future mandate far easier to meet.

Status as of November 2026

Standard or ruleStatusWhat it means
CSDS 1 and CSDS 2Canadian Sustainability Standards BoardVoluntaryCanada’s versions of the ISSB standards IFRS S1 and S2, effective for periods beginning on or after January 1, 2025. They apply when a regulator or law adopts them, or when you choose to use them. Proposed amendments to the GHG requirements in CSDS 2 would take effect in 2028.
Climate-related disclosure ruleCanadian Securities AdministratorsPausedThe CSA paused its mandatory climate disclosure rule in April 2025. Listed issuers must still disclose material climate-related risks under existing securities law.
Guideline B-15OSFIIn forceClimate risk management and disclosure for federally regulated banks and insurers, aligned with CSDS 2 in 2025. Scope 3 disclosure is expected from 2028.
Environmental claimsCompetition ActIn forceClaims about the environmental benefits of a business or product must be substantiated. Bill C-15 (Royal Assent March 26, 2026) removed the “internationally recognized methodology” test and private access to the Tribunal for these claims.
GHG ProtocolWRI and WBCSDUnder revisionThe basis of almost every corporate inventory. The Scope 2 consultation closed in January 2026; a combined consultation is planned for 2027 and a joint GHG Protocol–ISO corporate standard for late 2028.
Sustainability assuranceIAASB ISSA 5000 · AASB Canada CSSA 5000Effective 2027Standards for assuring sustainability information. CSSA 5000 applies to periods beginning on or after December 15, 2027, with early application permitted.
Large-building reportingOntario, Toronto, Montréal, VancouverIn forceAnnual energy and emissions reporting for large buildings, and in Vancouver, emissions limits for large offices and retail. See Net Zero Building. Details
SB 253CaliforniaIn forceLarge companies doing business in California report Scope 1 and 2 emissions; the California Air Resources Board’s regulation was approved in October 2026.
CSRDEuropean UnionChangingBeing narrowed to the largest companies under the Omnibus simplification package, politically agreed in December 2025.

04 Contact

Discuss your reporting.

Tell us what you report, to whom and by when. We’ll reply to arrange a conversation.

Or outline your needs here

What matters most

Opens your email app with these details filled in. Nothing is sent until you press send.

Discuss your reporting